Home | About JCVJS | Editorial board | Ahead of print | Current Issue | Archives | Instructions | Subscribe | Advertise | Contact us |   Login 
Journal of Craniovertebral Junction and Spine
Search Articles   
    
Advanced search   
 
ORIGINAL ARTICLE
Year : 2017  |  Volume : 8  |  Issue : 2  |  Page : 97-102

Atlas instrumentation guided by the medial edge of the posterior arch: An anatomic and radiologic study


1 Department of Surgery, Division of Neurosurgery, College of Medicine, King Saud University, Riyadh, Saudi Arabia
2 Department of Orthopedics, King Saud Bin Abdulaziz University for Health Sciences, Riyadh, Saudi Arabia

Correspondence Address:
Amro F Al-Habib
Department of Surgery, Division of Neurosurgery, College of Medicine, King Saud University, Post Box No: 59220, Riyadh 11525
Saudi Arabia
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jcvjs.JCVJS_36_17

Rights and Permissions

Study Design: This was an interventional human cadaver study and radiological study. Objectives: Atlas instrumentation is frequently involved in fusion procedures involving the craniocervical junction area. Identification of the entry point at the center of atlas lateral mass (ALM) is challenging because of its rounded posterior surface and the surrounding venous plexus. This report examines using the medial edge of atlas posterior arch (MEC1) as a fixed and reliable anatomic reference to guide the entry point of ALM screws. Methods: Fifty, normal, cervical spine computed tomography studies were reviewed. ALM screw trajectories were planned at one point along MEC1 and another point 2 mm lateral to MEC1. Free-hand ALM instrumentation was performed in ten fresh human cadavers using the 2 mm entry point, with a sagittal trajectory parallel to atlas inferior arch (IAC1); three-dimensional imaging was then performed to confirm instrumentation accuracy. Results: The average ALM diameter was 12.35 mm. Inserting a screw using the entry point 2 mm lateral to MEC1 was closer to ALM midpoint than using the entry point along MEC1 (P < 0.0001). Twenty ALM screws were successfully inserted in the ten cadavers. No encroachments into the spinal canal or foramen transversarium occurred. However, two screws were superiorly directed and violated the occipitocervical joint; they were not parallel to IAC1. Conclusion: MEC1 provides a fixed and reliable landmark for ALM instrumentation. An entry point 2 mm point lateral to MEC1 is close to ALM midpoint. IAC1 also provides a guide for the sagittal trajectory. Attention to anatomic landmarks may help reduce complications associated with atlas instrumentation but should be verified in future clinical studies.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1545    
    Printed18    
    Emailed0    
    PDF Downloaded18    
    Comments [Add]    

Recommend this journal